EAST stock code: 300376

EA900 1-20 kVA (120V)

Characteristics Technical Specifications Documents

l  High frequency and true double-conversion

l  DSP digital control technology

l  Input power factor correction (PFC)

l  Wide input voltage range

l  Output power factor 1.0 on 6~20KVA

l  Cold start

l  Auto sensing frequency

l  ECO mode operation for energy saving

l  Selectable output voltage via LCD

l  Output bypass settable for 1, 2, 3KVA via LCD

l  50Hz/60Hz frequency conversion mode available on 6~20KVA

l  6~20KVA built in output isolation transformer

l  Selectable battery low voltage via LCD

l  Power-on self test

l  Advanced battery management (ABM)

l  Short circuit and overload protection

l  Automatic charging battery in OFF mode

l  Fan speed auto control when loads varies

l  Standard RS232 communication port and RJ45 protection

l  Optional USB/SNMP communication port

l  Optional emergency power off (EPO)

l  Optional extension battery bank

l  Optional manual bypass on 6~20KVA

l  Optional N+X redundancy parallel on 6~20KVA


MODEL

EA901

EA902

EA903

EA906

EA9010

EA9020

Capacity

1KVA/900W

2KVA/1800W

3KVA/2700W

6kVA/6000 W

10kVA/10000 W

20kVA/20000 W

INPUT

Rated voltage

100Vac/110Vac/115Vac/120Vac/127Vac

208/220/230/240Vac

Voltage range

50~80Vac (linear derating between 50% and 100% load); 80~150Vac (no derating);

110~176Vac (linear derating between 50% and 100% load); 176~288Vac (no derating)

Frequency

45~55Hz ±0.5% or 55~65Hz ±0.5% (auto-sense)

50/60Hz (auto-sensing)

Power factor

≥0.98

≥0.99

Bypass voltage range

(90~140) ±5Vac

-40%~+15% (settable)

OUTPUT   

Voltage

100Vac/110Vac/115Vac/120Vac/127Vac (settable via LCD)

208 (PF=0.9) /220/230/240Vac or 110/115/120Vactwo groups, their phase angles different by 180°

Voltage regulation

±1%

±5%

Frequency

Synchronized with utility in mains mode; 50/60 ±0.2Hz in battery mode

Synchronized to bypass in mains mode; 50/60Hz ±0.1%Hz in battery mode

Waveform

Sinusoidal

Crest factor

3:1

Harmonic distortion

≤3% (linear load); ≤5% (non-linear load)

≤3% (linear load); ≤6% (non-linear load)

Transfer time

Mains mode to battery mode: 0ms

0ms

Inverter model to bypass mode: 4ms (typical)

Overload capability

105%~150%: transfer to bypass in 30s;

>150%: transfer to bypass in 300ms

105%~110% for 10min,

110%~125% for 1min,

126%~150% for 30s

BATTERIES

DC voltage

24V

48V

72V

192Vdc (192~240Vdc settable)

Inbuilt battery of standard model

2×9Ah

4×9Ah

6×9Ah

12V/7Ah×16

12V/9Ah×16

12V/9Ah×16(two groups)

Charging current

1A

Typical recharge time

8 h

90%   capacity restored in 8 hours

SYSTEM

Efficiency

≥90% in mains mode;

≥87% in battery mode;

≥94% in ECO mode

Max. 89.5%(max. 93% in ECO mode)

Max. 90%(max. 93% in ECO mode)

Communications

RS232(standard), USB/SNMP (optional)

RS232(standard), USB/RS485/dry contacts/SNMP/battery temperature compensation (optional)

OTHERS

Humidity

20~90% RH @ 0~40 (non-condensing)

0~95% (non-condensing)

Noise level

≤50dB (1m)

≤55dB

≤58dB

Dimensions (mm)

W×D×H

144×357×215

190×452×341

262×712×732

350×745×1183

Packaged dimensions (mm) W×D×H

232×457×320

320×573×472

382×825×931

 

460×890×1366

 

Net/Gross weight (kg)

11.0 / 13.5

20.0 / 21.5

24.0 / 25.5

93.0 / 105.0

115.0 / 127.0

256.0 / 271.0


EA900 1-20kVA (120V) Datasheet - PDF

EA900 1-3kVA(120V) User Manual - PDF

EA900 6-20kVA(120V) User Manual - PDF

 