MODEL

EAHI-3000-SL

EAHI-3600-SL

EAHI-5000-SL

EAHI-6000-SL

PV INPUT

Max. input power

4680W

6500W

7800W

Max. input voltage

550Vdc

Rated input voltage

360Vdc

Start-up voltage

100Vdc

Min. operating voltage

150Vdc

MPPT voltage range

100~540Vdc

Max. input current

16A

16A

16A/16A

16A/16A

Max. short-circuit current

24A

24A

24A/24A

24A/24A

Number of MPPT

1

1

2

2

Number of

input strings per

MPPT

1

1+1

BATTERY INPUT

Battery type

Li-ion, Lead-acid battery

Voltage range

42~58Vdc

Max. charge current

66A

75A

100A

100A

Max. discharge current

66A

75A

100A

120A

Charging curve

3 Stages / Equalization

Lithium battery charging strategy

BMS self-adaption

AC INPUT(Grid)

Grid type

Single phase(L+N+PE)

Input voltage range

184~276Vac

Input frequency range

50±5Hz/60±5Hz

Max. input current

21.8A

26.2A

36.5A

40A

AC OUTPUT(Grid)

Rated output power

3000W

3600W

5000W

6000W

Max. apparent output power

3000VA

3600VA

5000VA

6000VA

Grid system mode

Single phase(L+N+PE)

Rated output voltage

220Vac/230Vac

Rated output frequency

50Hz/60Hz

Rated output current

13.6A/13.0A

16.4A/15.7A

22.7A/21.8A

27.3A/26.1A

Max. output current

13.6A

16.4A

22.7A

27.3A

Power factor

>0.99 (0.8 leading ~ 0.8 lagging)

THDI

≤3% (@ Rated Power)

AC OUTPUT(Back-up)

Rated output power

3000W

3600W

5000W

6000W

Max. apparent power

3000VA

3600VA

5000VA

6000VA

Output system mode

Single phase(L+N+PE)

Rated output voltage

230Vac (208/220/240Vac settable)

Rated output frequency

50Hz/60Hz

Rated output current@230V

13.0A

15.7A

21.8A

26.1A

Max. output current

14.4A

17.3A

24.0A

28.8A

THDV

≤3% (linear load)

Transfer time

≤20ms

EFFICIENCY

Max. efficiency

97.8%

MPPT efficiency

99.9%

PROTECTIONS

Protections

Over/under voltage, over/under-frequency, over load, output short-circuit, over temperature, residual current monitoring unit, output over-current, insulation resistance, anti islanding, surge protection

Output overvoltage protection

DC Type II/AC Type III

OTHERS

CommunicationsRS485, WIFI

Dimensions(W*H*D)

548x440x197mm

Net weight

21.4kg

24.8kg

Topology

High frequency isolation(for battery)

IP rating

IP65

Operating temperature

-25℃~+60℃ (>45℃ derating)

Cooling mode

Natural cooling

Altitude

4000m

Noise level at 1 m

≤25dB

Installation mode

Wall hanging

STANDARDS

Safety regulation

IEC/EN 62109-1/-2, AS62109

EMC

EN 61000-6-1/-2/-3/-4

Grid connection

CEI 0-21, DIN VDE V 0124-100:2020, VDE-AR-N 4105:2018,AS4777.2, NRS097-2-1, EN 50549-1