EAST stock code: 300376

Off-Grid Solar Inverter 200 W - 3000 W

Characteristics Technical Specifications Documents

● High reliability: adopt high-speed DSP control system, combine advanced SPWM technology and high-speed power MOS

● Operating mode selectable: energy storage priority or power supply priority

● No PID attenuation damage for solar panels to ensure their service life

● Flexible battery management system: auto switch three-stage charging mode shortens recharge time: wide charging current is selectable according to configured battery; flexible DOD (Depth of discharge) is settable to meet more applications

● AC input with effective online synchronous stabilizing technology

● Board MPPT input voltage range

● No-load auto shutdown function (optional)

● Settable frequency (50 Hz / 60 Hz)

● Mobile APP monitoring

 Auto Power-On/Off function; real-time monitoring, test and intelligent startup / shutdown by RS232 or USB interface communicating with PC; remote monitoring by optional SNMP networks


MODEL

GF500

GF1000

GF2000

GF2500

GF3000

GF200

Rated power

500 W

1000 W

2000 W

2500 W

3000 W

200W

Operating modes

Energy storage priority /   Power supply priority

PV INPUT

Max. input power

700 W

1400 W

2800 W

3500 W

3500 W

3500 W

Max. input voltage

60 Vdc

100 Vdc

150 Vdc

150 Vdc

150 Vdc

150 Vdc

Rated input voltage

48 Vdc

80 Vdc

120 Vdc

120 Vdc

120 Vdc

120 Vdc

Start-up voltage

15 Vdc

30 Vdc

60 Vdc

60 Vdc

60 Vdc

60 Vdc

Max. input current

43 A

43 A

43 A

53 A

53 A

53 A

MPPT voltage range

(Full load)

16 ~ 48 Vdc

33 ~ 80 Vdc

65 ~ 120 Vdc

Number of MPPTs

1

AC   INPUT

Input voltage

Bypass input   range: 0 ~ 132 Vac / 0 ~ 264 Vac

Rated input voltage: 100 / 110 / 115 /   120 Vac or 200 / 220 / 230 / 240 Vac

(2500 W is   only for 110 Vac; 3000 W is only for 220 Vac)

Input frequency

50 / 60 Hz ± 5% /   10% / 15% (settable)

OUTPUT

Output voltage

100 / 110 /   115 / 120 Vac ± 2% or 200 / 220 / 230 / 240 Vac ± 2% (settable)

(2500 W is   only for 110 Vac; 3000 W is only for 220 Vac)

Output   frequency

50 / 60 Hz ±   1% (auto-sensing)

Power factor

1

Waveform

Sinusoidal

THD

THDv 3% (linear load)

BATTERIES

Battery type

Lead-acid battery (default),   AGM / LIT / GEL / Flood battery (optional)

Rated voltage

12 Vdc

24 Vdc

48 Vdc

Charging current

5 ~ 50 A (settable)

PV charging: 50 A (max.)

AC charging: 20 A (max.)

 

5 ~ 65 A (settable)

PV charging: 65 A max.)

AC charging: 30 A (max.)

 

3 ~ 65 A (settable)

PV charging:  65 A (max.)

AC charging: 5 A (max.)

TRANSFER TIME

PV ↔ AC

3 ~ 6 ms (typical), ≤ 10 ms   (max.)

EFFICIENCY

Max. efficiency (resistive load)

≥ 78%

≥ 82%

≥ 85%

≥ 85%

≥ 85%

≥ 75%

MPPT efficiency

≥ 98% (max.)

OTHERS

Protections

Over/under   voltage, over/under-frequency, output overload, short-circuit, overdischarge,   overcharge, overtemperature, battery low voltage, battery reverse polarity, PV reverse polarity,  lightning protections

Communications

RS232 / USB / RS485 (standard), SNMP / Wi-Fi / GPRS (optional)

Display

LCD & LED

Standards

IEC 62040-1, IEC 62040-2, EN 62040-1, EN 62040-2, EN   61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4, EN 62109-1, EN 62109-2

IP   rating

IP 21

Operating   temperature

0 ~ 40

-35 ~ 40

Relative   humidity

≤ 93%

Altitude

≤ 1000 m; Above 1000 m, derating 1%   for each additional 100 m; Max. 4000 m

Noise   level at 1 m

< 50 dB

Dimensions

(W × D × H) (mm)

365.5 × 442 × 210

Packaged   dimensions

(W   ×   D   ×   H)   (mm)

455 × 520 × 283

Net   weight (kg)

16.6

19.5

30.4

32.8

38.5

13.4

Gross weight (kg)

18.1

21.0

31.9

34.3

40.0

14.9