EAST stock code: 300376

EA890 10 - 120KVA (3:3) (208V)

Characteristics Technical Specifications Documents

● Online double-conversion with full DSP control

● IGBT rectifier and high input power factor (﹥0.99)

● IGBT inverter with output isolation transformer

● 100% unbanlance load capacity

● Output power factor 0.9

● Generator compatible

● Support battery cold start and mains supply self-starting

● ECO mode operation for energy saving

● Perfect protective function

● 5.7 inches LCD touch screen, friendly human & machine interface

● Front access makes maintenance and replacement easy (50~120KVA)

● Intelligent self diagnose function, all kinds of fault protection, large capacity of history record storage

● High MTBE (﹥200,000 H)

● Low MTBE (﹤0.5 H)

● Standard emergency power off (EPO)

● Optional SNMP communication port

● Optional N+X redundancy parallel up to 6 units


                    MODEL

                    EA8910

                    EA8915

                    EA8920

                    EA8930

                    EA8940

                    EA8950

                    EA8960

                    EA8980

                    EA89100

                    EA89120

                    Capacity

                    10KVA
9KW

                    15KVA
13.5KW

                    20KVA
18KW

                    30KVA
27KW

                    40KVA
36KW

                    50KVA
45KW

                    60KVA
54KW

                    80KVA
72KW

                    100KVA
90KW

                    120KVA 108KW

                    INPUT

                    Rated voltage

                    200 / 208 / 220 Vac

                    Voltage range

                    146 ~ 270 Vac (166 V ~ 250    Vac full load)

                    Rated frequency

                    50 / 60 Hz

                    Frequency range

                    50 / 60 Hz ± 5 Hz

                    Power factor

                    ≥ 0.99

                    Current distortion

                    ≤ 5%

                    Bypass voltage range

                    ± 20%

                    ECO voltage range

                    ± 10%

                    OUTPUT

                    Voltage

                    200 / 208 / 220 Vac

                    Voltage regulation

                    ± 1%

                    Frequency

                    Synchronized    with utility in mains mode; 50 / 60Hz ± 0.1% in battery mode

                    Waveform

                    Sinusoidal

                    Crest factor

                    3:1

                    Total harmonic distortion (THDV)

                    ≤ 1% (linear load); ≤ 5%    (non-linear load)

                    ≤    2% (linear load); ≤ 8% (non-linear load)

                    Transfer time

                    Mains mode to battery mode: 0 ms
Inverter model to bypass    mode: 0 ms
ECO mode to Inverter    model: max. 10 ms

                    Inverter overload capacity

                    105%: long time running;
105% ~ 110%: transfer to    bypass in 1 h
110% ~ 125%: transfer to bypass in 10 mins
125% ~ 150%: transfer to    bypass in 1 min
150% ~ 200%: transfer to    bypass in 100 ms
> 200%: transfer to bypass    in 100 ms

                    105%:    long time running;
105%    ~ 110%: transfer to bypass in 1 h
110%    ~ 125%: transfer to bypass in 10 mins
125%    ~ 150%: transfer to bypass in 1 min
150%    ~ 200%: transfer to bypass in 200 ms
> 200%: transfer to bypass in    100 ms

                    Bypass overload capacity

                    ≤ 150%: long time running
150% < load < 200%: shut down in 30 s
> 200%: shut down in 1 s

                    ≤ 150%: long time running
150% < load < 200%: shut down in 1 min
> 200%: shut down in 100 ms

                    BATTERIES

                    DC voltage

                    360 V (default 12 V × 30 pcs, 28 pcs ~ 32 pcs settable)

                    Inbuilt battery of standard model

                    Max. 60 × 12 V / 9 Ah    (optional external battery available)

                    External battery

                    Charger current

                    1.8 A (default);
Settable    according to battery configurations

                    100 A

                    150 A

                    150 A

                    200 A

                    200 A

                    SYSTEM

                    Alarm

                    Battery mode, battery    voltage low etc.

                    Battery mode, battery    voltage low, fans fault etc.

                    Surge protection

                    IEC 60664-1

                    Insulation resistance

                    > 2 MΩ (500 Vdc)

                    Dielectric strength

                    2820 Vdc, No arc in 1 min

                    IP rating

                    IP 20

                    EMI

                    EN 62040-2

                    EMS

                    IEC61000-4-2 (ESD)

                    IEC61000-4-3 (RS)

                    IEC61000-4-4 (EFT)

                    IEC61000-4-5 (surge)

                    COMMUNICATIONS

                    RS232 / RS485 / dry contacts    (standard)

                    Supports Windows 98 / 2000    / 2003 / XP / Vista / 2008 / 7 / 8 / 10

                    SNMP (optional)

                    Power management from SNMP    manager and web browser

                    OTHERS

                    Humidity

                    0~95% RH @ 0 ~ 40℃ (non-condensing)

                    Noise Level

                    ≤ 65dB

                    Dimensions (mm) W×D×H

                    500×800×1600

                    600×800×1600

                    800×900×1800

                    Packaged dimensions (mm) W×D×H

                    630×935×1775

                    690×990×1775

                    890×990×1975

                    Net / Gross weight (kg)

                    297 /315

                    297 / 315

                    325 / 343

                    372 / 388

                    402 / 420

                    460 / 480

                    590 / 620

                    630 / 660

                    690 / 720


EA890 10 - 120KVA (3:3) (208V) Datasheet - PDF


 
Online Support