EAST stock code: 300376

Outdoor UPS 500 - 3000 VA

Characteristics Technical Specifications Documents

● Strong environmental adaptability

● High reliability, energy saving, environmental protection

● Wide adaptability to power grid

● Unattended and intelligent monitoring (optional)

● Inverter isolation & pure sine wave technology

● Online UPS protection function

● Intelligent no-load shutdown (optional)

● Auto restart when mains power is restored


                MODEL                500 VA                1000 VA                2000 VA                3000 VA
                Capacity                300 W                600 W                1200 W                1800 W
                DISPLAY
                Panel indicator                LED
                MAINS STATES
                Applications
                PC, banking system, ATM, medical system
                Input voltage range
                100 / 110 / 115 / 120 / 200 / 220 / 230 / 240 Vac ± 25%
                Input frequency range
                45 ~ 65 Hz (over-frequency automatically transfer to inverter power)
                Stable output voltage range
                    174 ~ 216 Vac / 190 ~ 238 Vac / 199 ~ 250 Vac / 210 ~ 260 Vac ± 10 Vac for 200 / 220 / 230 / 240 Vac
                    87 ~ 108 Vac / 96 ~ 120 Vac / 100 ~ 125 Vac / 105 ~ 130 Vac ± 10 Vac for 100 / 110 / 115 / 120 Vac
                Input P.F. (AC/DC)
                98%
                Efficiency
                Mains mode ≥ 96%
                Mains overload
                110% for 120 s, 125% for 60 s , 150% for 10 s
                Short circuit
                Input fuse 
                INVERTER STATES
                Inverter output voltage
                100 / 110 / 115 / 120 / 200 / 220 / 230 / 240 Vac ± 5% (battery ≥ 11 Vdc)
                Output frequency
                50 / 60 Hz ± 1% (auto-sensing) 
                Output power factor
                ≥ 0.6
                Waveform distortion
                Linear load ≤ 5%
                Transfer time
                ≤ 10 ms
                Efficiency
                Inverter mode ≥ 80%
                Inverter overload
                110% for 60 s, 125% for 10 s , 150% for 5 s 
                No-load shut-off (option)
                Load < 5% auto shutdown in 1 min
                Short circuit
                the system automatically shut down
                ALARM
                Mains abnormal
                1 / 4 s, be silent in 40 s
                Low battery
                1 / 0.2 s
                Overload                1 / 1 s 
                BATTERIES
                DC voltage
                24 Vdc
                48 Vdc
                Inner battery space
                2 × 12 V 38 Ah / 120 Ah 

                    4 × 12 V 38 Ah / 120 Ah

                4 ×12 V 120 Ah
                Charging current
                Max. 12 A
                OTHERS
                Installing
                Floor standing or wall-mounted
                Surge protection
                Class C 
                Communications 
                Dry contacts / RS232 / USB / SNMP (optional)
                Protection grade
                IP 55
                Environmental temperature
                0℃ ~ 50℃
                Environmental humidity
                10% ~ 95% (no cooling)
                Noise
                ≤ 50 dB 
                Weight (kg)
                17.5 / 36.7
                36.7
                60.7

                    Dimensions (W x D x H) (mm) 

                    430 × 245 × 550 / 470 × 245 × 900

                470 × 245 × 900 / 470 × 460 × 900
                470 × 460 × 900

                    Packing dimensions (W x D x H) (mm)

                    500 × 335 × 636 / 540 × 330 × 980

                540 × 330 × 980 / 550 × 560 × 950
                550 × 560 × 950

● All specifications are subject to change without notice.