EAHI 3-6K
● Natural heat dissipation, no fan, low noise;
● IP65 outdoor protection grade, wall mounted design;
● Off grid and grid connected dual output, and the switching time is less than 20ms;
● Energy flows in both directions, and the battery can be charged and discharged at full power;
● Flexible open display menu, customers can set charging and discharging time period and power at any time, so as to facilitate time-of-use electricity price and earn income;
● App flexible monitoring system, multiple upgrade program modes, with isolated USB upgrade;
● Excellent off grid output performance, with air conditioning and other inductive loads;
● Beautiful appearance design and reasonable space layout make the weight lighter;
MODEL | EAHI-3K | EAHI-3.6K | EAHI-5K | EAHI-6K |
Rate power | 3000W | 3600W | 5000W | 6000W |
Operating mode | Flexible setting via upper computer software or display screen | |||
PV INPUT | ||||
Max. input power | 4680W | 4680W | 6500W | 7900W |
Max. input voltage | 550 Vdc | |||
Rated input voltage | 360 Vdc | |||
Start-up voltage | 100 Vdc | |||
Initial feeding voltage | 150 Vdc | |||
MPPT voltage range (Full load) | 100 ~ 540 Vdc (220 ~ 450 Vdc) | |||
Max. input current | 15A/15A | 15A | 15A/15A | 15A/15A |
Number of MPPTs | 1 | 2 | ||
AC OUTPUT | ||||
PHASE | Single phase(L+N+PE) | |||
Rated AC power | 3000VA / 3000W | 3600VA / 3600W | 5000 VA /5000W | 6000 VA / 6000W |
Rated output voltage | 230 Vac | |||
Output voltage range | 184 ~276 Vac | |||
Rated output frequency | 50 / 60 Hz | |||
Output frequency range | 50 ± 5 / 60 ± 5 Hz | |||
Rated output current | 13.05 A | 15.7 A | 21.8 A | 26.09 A |
Power factor | 0.8 (leading) ~ 0.8(lagging) | |||
THDI(@ Rated Power) | ≤ 3% | |||
EPS OUTPUT | ||||
Rated EPS power | 3000 VA / 3000W | 3600 VA / 3600W | 5000 VA /5000W | 6000 VA / 6000W |
Rated EPS voltage | 230 Vac (208 / 220 / 240 Vac settable) | |||
Rated EPS current | 13.05 A | 15.7 A | 21.8 A | 26.09 A |
EPS voltage range | 184 ~ 276 Vac | |||
EPS frequency range | 50 / 60 Hz ± 1% | |||
THDV | ≤ 3% (linear load) | |||
Over capacity | 110%,60S/120%,30S/150%,10S | |||
TRANSFER TIME | ≤ 20 ms | |||
BATTERY | ||||
Battery type | Li-ion, Lead-acid battery | |||
Rated voltage | 48 Vdc | |||
Voltage range | 42 ~ 58 Vdc | |||
Charging current | Max. 66A | Max. 75A | Max. 100A | Max. 100A |
AC charge | Support | |||
Max. charge voltage | 58V(Settable) | |||
Max. discharge current | 66A | 75A | 100A | 120A |
Charging curve | BMS(Lithium battery ) | |||
3-Stage( Lead-acid battery) | ||||
EFFICIENCY | ||||
Max. efficiency | 97.8% | |||
MPPT efficiency | 99.9% | |||
Battery charge discharge efficiency | 94% | |||
OTHERS | ||||
Protections | Over/under voltage, over/under-frequency, over load, short-circuit, over temperature, PV and battery reverse polarity, leakage current, insulation resistance, Anti islanding protection | |||
Communications | USB / RS485 (standard), SNMP / Wi-Fi / GPRS (optional) | |||
Warning | LED,Buzzer | |||
Display | LED/LCD | |||
Standards | EN 62109-1, IEC62109-2, EN 61000-6-2,EN 61000-6-3, VDE-AR-N 4105, DIN VDE 0126-1-1, DIN VDE V 0124-100, CEI 0-21,G83 | |||
IP rating | IP 65 | |||
Operating temperature | -25 ~ 60℃ (> 45℃ derating) | |||
Cooling mode | Natural cooling | |||
Installation mode | Wall hanging | |||
Relative humidity | 0 ~ 90% | |||
Altitude | ≤2000 m (> 2000 m derating) | |||
Noise level at 1 m | ≤ 25 dB | |||
Topology | Transformerless | |||
Dimensions (W×H×D) (mm) | 548×440×197mm | |||
Weight (kg) | 23.4kg |